acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

How to Replace Connector Terminals|Page 224 > < How to Replace Connector Terminals|Page 222
Page 3
background image

2. Connect one lead of a self-powered test light or digital volt/ohmmeter (DVOM) (switched to the lowest "OHMS" range) to the fuse terminal on the

load side.

3. Connect the other lead to a known good ground.
4. Beginning near the fuse box, wiggle the harness. Continue this at convenient points about six inches apart while watching the test light or DVOM.
5. If the self-powered test light goes on or the DVOM displays a low reading or no reading (zero), there is a short to ground in the wiring near that

point.

Testing for a Short with a Short Circuit Locator (Short Finder)

1. Remove the blown fuse. Leave the battery connected.

How to Replace Connector Terminals|Page 224 > < How to Replace Connector Terminals|Page 222