TL V6-3.2L (2004)
^
Clogged or deformed feed or return line between the pump and gearbox.
^
Clogged valve body unit.
10. Let the engine idle, and gradually close the shut-off valve and immediately read the pressure.
NOTICE: Do not keep the shut-off valve closed more than 5 seconds or the pump could be damaged by over-heating.
11. Immediately open the shut-off valve fully. If the pump is in good condition, the gauge should read at least 7,940 - 8,630 kPa (81 - 88 kgf/cm,
1,150 - 1,250 psi). A low reading means pump output is too low for full assist. Repair or replace the pump.