Fog/Driving Lamp Relay: Testing and Inspection

Normally-open type:

Normally-open Type-Power Relays Test

1.  Check for continuity between the terminals.

^  There should be continuity between the No. 1 and No. 3 terminals when power and ground are connected to the No. 2 and No. 4 terminals.
^  There should be no continuity between the No. 1 and No. 3 terminals when power is disconnected.

Fog Light Relay-Relay Test

^  Fog light relay