acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Lamps and Indicators - Transmission and Drivetrain > < Lock-Up Control Solenoid Valve A/B <--> [Torque Converter Clutch Solenoid, A/T]|Specifications|Page 3830
Page 1
background image

Lock-Up Control Solenoid Valve A/B: Service and Repair

Replacement

NOTE: Lock-up control solenoid valve A and B must be replaced as an assembly.

1. Remove the mounting bolts and lock-up control solenoid valve assembly.
2. Clean the mounting surface and fluid passages of the lock-up control solenoid valve assembly, and install a new lock-up control solenoid valve NB

with a new filter/gasket.
NOTE: Install the filter/gasket in the direction shown.

3. Check the connector for rust, dirt or oil, then reconnect it securely.