acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Trunk Lid Opener Main Switch Test/Replacement|Page 6060 > < Power Trunk / Liftgate Lock Switch|Locations
Page 1
background image

Power Trunk / Liftgate Lock Switch: Testing and Inspection
Trunk Lid Opener Main Switch Test/Replacement

Trunk Lid Opener Main Switch Test/Replacement

1. Remove the glove box housing  See: Interior Moulding / Trim/Glove Compartment/Service and Repair/Glove Box Removal/Installation.

2. Carefully push the main switch (A) out from behind the glove box housing.

3. Disconnect the 2P connector (B) from the trunk lid opener main switch.

4. Check for continuity between terminals No. 1 and No. 2.

-

With the main switch ON, there should be continuity.

-

With the main switch OFF, there should be no continuity.

5. If the continuity is not as specified, replace the main switch.

6. Install the switch in the reverse order of removal.

Trunk Lid Opener Main Switch Test/Replacement|Page 6060 > < Power Trunk / Liftgate Lock Switch|Locations