NOTE:

Place a shop towel inside the center console cavity, under the area you are filing, so that the metal filings do not fall on any harnesses or
components.

15. Install a new ground bolt using the hardware from the kit.

^

Insert the ground bolt into the G403 ground terminal.

^

Insert the ground bolt through one of the washers.

^

Insert the ground bolt through the square opening on the lower stay bracket.

^

Make sure that the anti-rotation tab on the terminal is inserted into the anti-rotation hole located below the square opening.

^

With the ground bolt inserted in the square opening, mount a washer and the flange nut on the back side of the lower joint stay bracket.

^

Torque the ground bolt to 12 N.m (9 lb-ft).