background image

6. Reconnect the negative cable to the battery, and turn the ignition switch to ON (II) or press the engine start/stop button to select the ON mode (but

do not operate the starter motor). The fuel pump runs for about 2 seconds, and fuel pressure rises. Repeat this two or three times, and make sure
there are no fuel leaks.

7. If equipped, install the quick-connect fitting cover. Set the groove of the cover (A) on the fuel line (B) as shown, then install it. Make sure the

cover is firmly locked in place.