acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Procedures|Page 3134 > < Procedures
Page 2
background image

3. Flip the HEAT toggle switch to ON; the green indicator above the toggle switch comes on. Wait 1 hour   for the cooler cleaner to reach its

operating temperature. (The cooler cleaner is ready to use when the temperature gauge reads 140 °F to 150 °F.)

NOTE: If the red indicator above the HEAT toggle switch comes on, the fluid level in the tank is too low for the tank heater to work (see step 1   of this
procedure).

4. Select the appropriate pair of fittings, and attach them to the radiator, to the hoses, or to the banjo bolts for flow through the ATF cooler cleaner.

5. Connect the red hose to the cooler outlet line (the line that normally goes to the external filter on the transmission).

6. Connect the blue hose to the cooler inlet line.

7. Connect a shop air hose (regulated to 100 to 125 psi)   to the air purge valve.

NOTICE
The quick-connect fitting has a one-way check valve to keep ATF from entering your shop's air system. Do not remove or replace the fitting.
Attach the coupler provided with the cooler cleaner to your shop air line if your coupler is not compatible.

8. Flip the MOTOR toggle switch to ON; the green indicator above the toggle switch comes on. Let the pump run for 5 minutes. While the pump is

running, open and close the air purge valve periodically to cause agitation and improve the cleaning process. Always open the valve slowly. At the
end of the 5-minute   cleaning period, leave the air purge valve open.

NOTE: While the pump is running with the air purge valve open, it is normal to see vapor coming from the filler/breather tube vents.