TL FWD V6-3.5L (2009)
Blower Motor: All Technical Service Bulletins
A/C, Electrical - Blower Changes Speed/DTCs 104/86
09-057
March 19, 2010
*Applies To:
2009 TL - ALL
2010 TL Base - From VIN 19UUA8...M000001 thru 19UUA8...AA008856
2010 TL Tech - From VIN 19UUA9...AA000001 thru 19UUA9...M003620*
Blower Speed Changes and VSA DTCs 104 and/or 86 Are Stored (Supersedes 09-057, dated January 9, 2010, to revise the information marked by
asterisks)
*REVISION SUMMARY
In Applies To, the applicability to 2010 models has been narrowed to two specific VIN ranges.*
SYMPTOM
The HVAC blower speed changes erratically and VSA DTCs 104 and/or 86 are stored.
PROBABLE CAUSE
The body ground G403 is faulty.
CORRECTIVE ACTION
Replace the body ground hardware for G403.
PARTS INFORMATION
Hardware Kit: P/N 61336-TK4-305
TOOL INFORMATION
KTC Trim Tool Set: T/N SQJATP2014
WARRANTY CLAIM INFORMATION
The normal warranty applies.
Operation Number:
8410B8
Flat Rate Time:
1.7 hours
Failed Part:
P/N 61313-TK4-305
Defect Code:
06201
Symptom Code:
03220
Skill Level:
Repair Technician
REPAIR PROCEDURE
NOTE:
This procedure is in an outline form that you can also use as a checklist for the repair. If you need more details, bookmark the following procedures
in the 2009-10 TL Service Manual, or view them online:
^
Center Console Rear Trim Removal/Installation
^
Center Console Removal/Installation
^
Battery Terminal Disconnection and Reconnection