Thermostat Housing: Service and Repair

Water Outlet Replacement

1. Drain the engine coolant.

2. Remove the two bolts (A) securing the evaporative emission (EVAP) canister purge valve bracket and remove the bolt (B) securing the harness

bracket.

3. Remove the upper radiator hose (A), heater hose (B), water bypass hose (C), and connecting pipe mounting bolt (D).

4. Remove the water outlet (A).
5. Install the water outlet with a new gasket (B).
6. Install the other parts in the reverse order of removal.
7. Refill the radiator with engine coolant, and bleed air from the cooling system with the heater valve open.