Air Door Actuator / Motor: Service and Repair
Recirculation Control Motor

Recirculation Control Motor Replacement

1. Open the glove box. Remove the damper from the glove box, then let the glove box hang down.

2. Remove the relays from the bracket.

3. Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor

from the blower unit.

4. Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make

sure the motor runs smoothly.