Control Assembly: Testing and Inspection
Non-Trouble Code Procedures

Climate Control Power and Ground Circuit Troubleshooting

1. Check the No. 30 (7.5 A) fuse in the under-dash fuse/relay box.

Is the fuse OK?

YES - Go to step 2.

NO - Replace the fuse, and recheck.

2. Disconnect audio-HVAC display panel connector B (16P).
3. Turn the ignition switch ON (II).

4. Measure the voltage between the No. 4 terminal of audio-HVAC display panel connector B (16P) and body ground.

Is there battery voltage? 

YES - Go to step 5.

NO - Repair open in the wire between the No. 30 fuse in the driver's under-dash fuse/relay box and the audio-HVAC display panel.

5. Turn the ignition switch OFF.

6. Check for continuity between the No. 6 terminal of audio-HVAC display panel connector B (16P) and body ground.

Is there continuity?

YES - Check for loose wires or poor connections at audio-HVAC display panel connector B (16P). If the connections are good, substitute a
known-good audio-HVAC display panel, and recheck. If the symptom/indication goes away, replace the original audio-HVAC display panel.

NO - Check for an open in the wire between the audio-HVAC display panel and body ground. If the wire is OK, check for poor ground at G503.