TSX L4-2.4L (2005)
specification:
7,850 - 8,550 kPa (80 - 87 kgf/cm, 1,140 - 1,240 psi)
A low reading means pump output is too low for full assist. Repair or replace the pump.
specification:
7,850 - 8,550 kPa (80 - 87 kgf/cm, 1,140 - 1,240 psi)
A low reading means pump output is too low for full assist. Repair or replace the pump.