acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

VSA System Component Location Index|Page 3443 > < VSA System Component Location Index|Page 3441
Page 1
background image

Traction Control Module: Testing and Inspection

VSA Modulator-Control Unit Update

Special Tools Required

-

Honda Diagnostic System (HDS) tablet tester

-

Honda Interface Module (HIM) and an iN workstation with the latest HDS software version

-

HDS pocket tester

-

GNA600 and an iN workstation with the latest HDS software version

Any one of the above updating tools can be used.

NOTE:

-

Use this procedure when you need to update the VSA modulator-control unit at anytime.

-

Make sure the HDS/iN workstation has the latest HDS software version.

-

Before you update the VSA modulator-control unit, make sure the battery in the vehicle is fully charged, and connect a jumper battery (not a
battery charger) to maintain system voltage.

-

Never turn the ignition switch to LOCK (0) or ACC (I), or press the engine start/stop button to select the OFF or ACC mode, during the update. If
there is a problem with the update, leave the ignition switch ON (II), or the ON mode.

-

To prevent VSA modulator-control unit damage, do not operate anything electrical (headlights, audio system, brakes, A/C, power windows, door
locks, etc.) during the update.

-

To ensure the latest program is installed, do a VSA modulator-control unit update whenever the VSA modulator-control unit is substituted or
replaced.

-

You cannot update a VSA modulator-control unit with a program it already has. It will only accept a new program.

-

High temperature in the engine compartment might cause the VSA modulator-control unit to become too hot to run the update. If the engine has
been running before this procedure, open the hood and cool the engine compartment.

-

If you need to diagnose the Honda interface module (HIM) because the HIM's red (ïVƒ3) light came on or was flashing during the update, leave
the ignition switch in ON (II), or in the ON mode when you disconnect the HIM from the data link connector (DLC). This will prevent VSA
modulator-control unit damage.

-

DTCs stored in memory are cleared when the VSA modulator-control unit is updated.

1. Turn the ignition switch to ON (II), or press the engine start/stop button to select the ON mode, but do not start the engine.

2. Connect the HDS to the data link connector (DLC) (A) located under the driver's side of the dashboard.

3. Make sure the HDS communicates with the vehicle and the VSA modulator-control unit. If it doesn't troubleshoot the DLC circuit  See: Powertrain

Management/Computers and Control Systems/Testing and Inspection/Component Tests and General Diagnostics/DLC Circuit Troubleshooting.

4. Select the update mode, and follow the screen prompts to update the VSA modulator-control unit.

5. If the software in the VSA modulator-control unit is the latest, disconnect the HDS/HIM/GNA600 from the DLC. If the software in the VSA

modulator-control unit is not the latest, follow the instructions on the screen.

6. Do the VSA sensor neutral position memorization procedure  See: Testing and Inspection/Programming and Relearning/VSA Sensor Neutral

Position Memorization.

VSA System Component Location Index|Page 3443 > < VSA System Component Location Index|Page 3441