8. Pour Acura Long Life Antifreeze/Coolant Type 2 into the radiator up to the base of the filler neck.

NOTE:

-

Always use Acura Long Life Antifreeze/Coolant Type 2. Using a non-Acura coolant can result in corrosion, causing the cooling system to
malfunction or fail.

-

Acura Long Life Antifreeze/Coolant Type 2 is a mixture of 50 % antifreeze and 50 % water. Do not add water.

9. Loosely install the radiator cap.

10. Start the engine, and let it run until it warms up (the radiator fan comes on at least twice).

11. Turn off the engine. Check the level in the radiator, and add Acura Long Life Antifreeze/Coolant Type 2, if needed.

12. Put the radiator cap on securely, then run the engine again, and check for leaks.

13. Clean up any spilled engine coolant.

14. If the maintenance minder required engine coolant replacement, reset the maintenance minder  See: Instrument Panel, Gauges and Warning

Indicators/Maintenance Required Lamp/Indicator/Description and Operation, and this procedure is complete. If the maintenance minder did not
require engine coolant replacement, go to step 15.

15. Turn the ignition switch to LOCK (0), or press the engine start/stop button to select the OFF mode.

16. Connect the Honda Diagnostic System (HDS) to the data link connector (DLC)  See: Powertrain Management/Computers and Control

Systems/Testing and Inspection/Initial Inspection and Diagnostic Overview.

Cooling System|Capacity Specifications|Page 1758 > < Cooling System|Capacity Specifications|Page 1756