Connecting Rod: Testing and Inspection

Connecting Rod and Crankshaft End Play Inspection

1. Remove the oil pump  See: Engine Lubrication/Oil Pump/Service and Repair.

2. Remove the baffle plate  See: Crankshaft/Service and Repair/Crankshaft and Piston Removal.

3. Measure the connecting rod end play with a feeler gauge (A) between the connecting rod (B) and the crankshaft (C).

Connecting Rod End Play

4. If the connecting rod end play is beyond the service limit, install a new connecting rod and recheck. If it is still beyond the service limit, replace

the crankshaft  See: Crankshaft/Service and Repair/Crankshaft and Piston Removal.

5. Push the crankshaft firmly away from the dial indicator, and zero the dial against the end of the crankshaft. Then pull the crankshaft firmly back

toward the indicator; the dial reading should not exceed the service limit.

Crankshaft End Play

6. If the end play is excessive, replace the thrust washers and recheck. If it is still beyond the service limit, replace the crankshaft  See:

Crankshaft/Service and Repair/Crankshaft and Piston Removal.