acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Fuel Delivery and Air Induction > < Positive Crankcase Ventilation Valve|Testing and Inspection
Page 1
background image

Positive Crankcase Ventilation Valve: Service and Repair

PCV Valve Replacement

1. Remove the engine cover  See: Engine, Cooling and Exhaust/Engine/Intake Manifold/Service and Repair/Intake Manifold Removal/Installation.

2. Lift up the engine harness holder (A).

3. Remove the bolt (B).

4. Remove the PCV valve (C).

NOTE: Take care not to spill oil on the hot exhaust manifold.

5. Install the parts in the reverse order of removal.

NOTE:

-

When installing a new PCV valve, make sure the O-rings (D) are in place.

-

When installing a used PCV valve, use new O-rings.