audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Restraint Systems > < All Technical Service Bulletins for Ventilation Fan Motor:|879405
Page 1
background image

Ventilation Fan Motor: Customer Interest
Fresh Air Fan - Intermittently Switching to High Speed

Group: 87

Number: 94-05

Date: Aug. 1, 1994

Subject:
Fresh Air Fan, Intermittent switching to high speed

Model(s):
90 (with manual a.c. system) m.y. 93-94 
100 (with manual a.c. system) m.y. 92-94

Condition

Inconsistent manufacturing tolerances on fresh air fan resistor packs, causing high speed fan operation when it is not necessary. The resistor pack has a
bi-metallic strip that allows the fresh air fan to cool the resistor pack.

Production

Manual a/c system fresh air fan resistor packs have been upgraded as follows:

New part numbers are:
90 model vehicles: 8A0 959 263 A 
100 model vehicles: 4A0 959 127 B

Service

If this symptom is encountered, install updated version.

Caution:

Part numbers are supplied for information only - please check with parts department for latest in formation.

Restraint Systems > < All Technical Service Bulletins for Ventilation Fan Motor:|879405