200 Quattro Wagon L5-2226cc 2.22L SOHC Turbo (MC) (1989)
Air Door Actuator / Motor: Testing and Inspection
Flap Position Checking
FLAP POSITIONS, CHECKING
The Climate Control memory display channel 7 displays the control information to the A/C programmer.
Memory Display Channel 7
-
Segment 1 lights or flashes
Temperature regulating flap E moves in direction 2 "heating": See Channel 18
-
Segment 2 lights
Recirculation/fresh air flap A is in position 2 "recirculation mode
-
Segments 3 and 5 light up
Regulating flap B (footwell/defrost outlet) is in position 1 "air from instrument panel outlets"
-
Segment 4 lights up
Heater valve D is in position 1 (closed)
Regulating Flap Positions
-
Segment 5 lights up (segment 3 does not light up)
Regulating flap B (outlets for footwell/defrost) in position 2 "air from instrument panel outlets and to regulating flap (footwell/defrost)"
-
Segment 6 lights up
Regulating flap C (footwell/defrost) is in position 2 "air from footwell outlets"
-
Segment 7 lights up or flashes
Temperature regulating flap E moves in direction 1 "cooling": see Channel 18
-
Segment 8 lights up
Compressor on
-
Segment 9 lights up