High Pressure Sensor / Switch: Service and Repair

High Pressure Switch

NOTE:  

This switch can be removed without discharging the refrigerant system (Schrader valve under switch).

1. Disconnect electrical connector.
2. Remove refrigerant high pressure switch.
3. Install refrigerant high pressure switch.
4. Torque to 10.0 Nm (7.5 ft lb).
5. Inspect electrical connector for damage or corrosion.
6. Refasten electrical connector.