audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Ambient Temperature Sensor / Switch HVAC|Specifications|Page 4972 > < Ambient Temperature Sensor / Switch HVAC|Specifications|Page 4970
Page 1
background image

Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

TEST CONDITIONS

-

Fuses OK (check according to wiring diagram.

-

Ambient temperature above 10° C (50° F).

-

Engine at normal operating temperature.

-

Vehicle not parked in direct sunlight.

Use Chart 3 to determine calculated outside temperature.

Example:  If Channels 4 or 5 display a code of 73 on Control head, calculated temperature according to Chart 3 is 86°F (30°C).

NOTE:  

The diagnostic value displayed on Channels 4 and 5 may stay at 128 if fault is with the sensor.

Outside Temperature Sensors, Chart 1 Of 3

Chart 1 of 3

Ambient Temperature Sensor / Switch HVAC|Specifications|Page 4972 > < Ambient Temperature Sensor / Switch HVAC|Specifications|Page 4970