audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

A/C Refrigerant High Pressure Switch (-F23-)|Page 5004 > < Mechanical Specifications|Page 5001
Page 1
background image

High Pressure Sensor / Switch: Description and Operation
A/C Refrigerant High Pressure Switch (-F23-)

The A/C Refrigerant High Pressure Switch turns ON the radiator cooling fan 2nd stage operation when refrigerant pressure reaches specified value.
Activation time varies by ambient temperature and engine RPM.

-

Switch has yellow housing or green housing with welded wiring connections.

-

Maximum 17.5 bar on high pressure side to activate.

-

Closes:  13.1 bar - 17.5 bar (189.9 psi - 253.7 psi).

-

Opens:  10.6 bar - 15.0 bar (153.7 psi - 217.5 psi).

-

Opening and closing switching points must be at least 2 bar (29 psi) difference.

NOTE: 

This switch can be removed without discharging the refrigerant system.

A/C Refrigerant High Pressure Switch (-F23-)|Page 5004 > < Mechanical Specifications|Page 5001