audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Engine With One Knock Sensor|Page 1189 > < Air/Fuel Mixture|Specifications
Page 1
background image

Air/Fuel Mixture: Adjustments
Engine With One Knock Sensor

Requirements:

Engine at normal operating temperature, 80°C (176°F).
All electrical consumers (A/C, rear window defroster, etc.).
Radiator fan must not be running while checking or adjusting.
No fuel pressure gauges connected to the fuel system.
Throttle valve in the proper idle position.
Throttle valve switch must be adjusted properly and working.
Exhaust system must be tight and free from leaks.
Oxygen sensor system in good working order.

NOTE: If the injection lines were loosened or replaced, run the engine up to at least 3000 RPM several times to clear the system of trapped air before

making adjustments. 

1.

Initial setup

a. Remove the cap from the charcoal canister 'T' fitting (located near the fuel distributor).
b. Remove the breather hose from the elbow fitting at the valve cover.  Plug the hose that is still connected to the valve cover.
c. Connect an exhaust gas analyzer to the exhaust manifold sampling port.
d. Connect a tach-dwell meter to the engine.

 

Connecting Ammeter To Idle Stabilizer Valve

e. Disconnect the idle stabilizer valve harness plug, and install a test harness (VW 1315 A/2 or use set-up as shown in diagram) between the

valve and the harness connector.

f.

Connect a multimeter to the test harness, set to 2 Amp range.

2.

Check Idle Speed

a. Start the engine and let it idle.
b. Idle speed should be;

Manual Trans. .......... 800 +/- 50 RPM
Automatic Trans. ...... 720 +/- 50 RPM

c. If the idle speed is not within specification, adjust the speed by turning the throttle bypass screw in the throttle housing.
d. Disconnect the green wire from terminal 1 of the ignition coil junction block (located on the ignition coil) to activate the idle stabilizer preset

value.

Engine With One Knock Sensor|Page 1189 > < Air/Fuel Mixture|Specifications