audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Relays and Modules - Fuel Delivery and Air Induction > < Voltage Measurements|Page 1469
Page 1
background image

Engine Control Module: Testing and Inspection
Ohms Measurements

25 Position ECU Plug

For Terminal ID please refer to "Powertrain Management : Computers and Control Systems : Engine Control Module : Connector Views".  See:
Diagrams/Connector Views

CAUTION: When measuring Ohms disconnect the ECU from the harness plug and never turn the ignition key on.  It is possible that failure to follow

these steps will result in damage to the ECU.

GROUNDS

KEY OFF

Pin 2 to G1 ...........................................................................................................................................................................................  CONTINUITY
Pin 2 to 7 .............................................................................................................................................................................................  CONTINUITY
Pin 2 to 15 ...........................................................................................................................................................................................  CONTINUITY
Pin 2 to 20 ...........................................................................................................................................................................................  CONTINUITY
Pin 2 to 22 ...........................................................................................................................................................................................  CONTINUITY

COOLANT TEMPERATURE SENSOR

Pin 2 to 21

68°F ...............................................................................................................................................................................................  2200 - 2700 Ohms
176-194°F ..........................................................................................................................................................................................  200 - 350 Ohms

THROTTLE SWITCH

Pin 1 to 13 (Closed) ...................................................................................................................................................................................  CONTINUITY
Pin 1 to 5 (Full load) ..................................................................................................................................................................................  CONTINUITY

ALTITUDE SENSOR

Disconnect Air Flow Sensor when measuring ohms for Altitude sensor.
Changes with Altitude

Pin 14 to 18 ....................................................................................................................................................................................  2100 - 2600 Ohms
Pin 14 to 11 ......................................................................................................................................................................................  200 - 3800 Ohms
- Readings from pin 14 to 11 will depend on altitude.

ISC VALVE

Winding(s) 

Pin 1 to 3 ................................................................................................................................................................................................  20 - 24 Ohms
Pin 1 to 4 ................................................................................................................................................................................................  20 - 24 Ohms
Pin 3 to 4 ................................................................................................................................................................................................  40 - 48 Ohms

ELECTRO-HYDRAULIC ACTUATOR

Winding(s)

Pin 10 to 12 ............................................................................................................................................................................................  17 - 22 Ohms

AIR FLOW SENSOR

Disconnect Altitude sensor when measuring ohms on Air Flow Sensor.
At rest

Pin 14 to 18 (supply) ......................................................................................................................................................................  3800 - 4200 Ohms
Pin 14 to 17 (load) ...........................................................................................................................................................................  700 - 1200 Ohms

Flap on air flow sensor closed or air flow senor plate at rest position. Resistance increases as flap or plate opens.

Pin 14 to 17 (load) .........................................................................................................................................................................  4200 - 5600 Ohms

Flap on air flow sensor opened to maximum or air flow plate deflected to maximum.