audi Workshop Repair Guides

Audi 4000S Diesel L4-1588cc 16L DSL SOHC Workshop Manuals

Body and Frame|Mirrors > < Power Door Locking System - Component R&R|Page 1375
Page 5
background image

-

reinstall operating valve

-

check system for proper function

Note

When system is functioning properly, all locks must close within two seconds. If bi-pressure pump runs more than five seconds, system has leak. Control
valve in bi-pressure pump should shut off pump after 35 seconds.