audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Low Pressure Fuel Delivery|General|Page 651 > < Low Pressure Fuel Delivery|General|Page 649
Page 1
background image

Diesel MFI Pump: Description and Operation
Pressure Control Valve

Fig. 4 Pressure Control Valve

    The pressure-control valve, Fig. 4, is mounted very close to the supply pump and connected with the upper recess by a bore. It is a spring-loaded
slider valve with which the pump-housing pressure can be varied according to the quantity of fuel being delivered. If fuel pressure exceeds a preset
value, the valve piston opens the return circuit and allows fuel to flow back to the pump's suction side. If fuel pressure is too low, this return circuit
remains closed. The valve's opening pressure is determined by adjusting the spring preload.

Low Pressure Fuel Delivery|General|Page 651 > < Low Pressure Fuel Delivery|General|Page 649