Air Door Cable: Adjustments
Up to VIN GA 053 400
ADJUST
-
Disconnect heater flap cable at programmer.
-
Inner cable end must not come up against the lever arm.
-
Disconnect cable clip on heat exchanger housing.
-
Turn ignition on.
-
Set maximum heat output 9O°F (32°C) AUTO on control head.
-
Wait two minutes.
-
Reattach cable to programmer.
-
Push cable sleeve in the direction of arrow until heater flaps for temperature regulation come against stop.
-
Install cable clip.
CHECK ADJUSTMENT
-
Engine warm and idling.
-
Set control head to Auto 9O°F (32°C).
-
Wait 2 minutes.
-
Check cable adjustment at heat exchanger housing.
-
Set control head to Auto 6O°F (15°C).
-
Wait 2 minutes.