5000CD Turbo (Canada) L5-2144cc 2.14L SOHC Turbo (KH) (1984)
-
connect ohmmeter between contacts 31 and 1
^
specified value approx. infinity ohm
-
push function selector switch to left for time display
^
specified value: approx. 0.0 ohm
-
connect ohmmeter between contacts 31 and 2
^
specified value: infinity ohm
-
push function selector button to right
^
specified value: 0.0 ohm
Note
If one of specified values is not attained, - replace function selector switch
Function Selector Switch Connector
If all specified values were attained, - check wires between 6-point selector button connector and 25-point connector of computer control unit
-
connect ohmmeter as follows:
6-point connector
25-point connector
31
and
4
R
and
3
2
and
2
1
and
1
^
specified value: 0.0 ohm
Computer Control Unit Connector
-
connect 25-point connector to computer control unit