Electronic Spark Control Module: Testing and Inspection

CAUTION; Be sure that test connections to the switching module harness plug are correct.  If the positive terminal is grounded, damage to the
ignition control unit will result.

1.

Inspect the blue wire between ignition coil terminal 1, and the switching unit for signs of corrosion or damages insulation and repair as necessary.

2.

Remove the coil wire from the distributor cap and connect it to ground with a jumper wire.

Fig. 8  Ignition Coil Power Stage Switching Module

3.

With the ignition OFF, disconnect the harness plug from the switching unit next to the ignition coil.

Fig. 10  Two Terminal Plug I.D.

4.

Connect terminal 1, of the harness plug, to ground with a jumper wire.

5.

Connect a voltmeter between terminal 2 (green/white wire), and ground.

Voltage should be 0.2 vdc while cranking the starter.

6.

If voltage is not correct, check wiring between the harness plug and the ignition control unit.

7.

If wiring is OK, replace the control unit.