5000S Wagon L5-2226cc 2.22L SOHC (KZ) (1985)
Computer Range Reading, Calibrating
Computer range reading, calibrating
Note
Calibrate the range reading only after performing the following repairs:
^
replacing sender for fuel gauge
^
replacing computer (when range reading defective)
Note
Calibrate range reading with full fuel tank.
-
press reset button with ignition switched OFF and hold
-
switch ignition ON
-
release reset button
^
display: approx. 700-800
Adjust Range Reading with Allen Wrench
-
adjust range reading with Allen wrench (arrow)
Note
The range calibrating screw can be turned only 1/2 turn between stops
Specified value:
^
750
If the specified value is not attained, - check fuel gauge
-
repeat range calibration
If the specified value still is not attained, - replace computer module