background image

-

connect multimeter US 1119 between terminal 2 of cold start valve connector and terminal 16 of fuel injection control unit connector
^

specification: approximately 0.2 ohms 

If specification is NOT obtained

-

repair break in wiring, using wiring diagram

If specification IS obtained

-

replace fuel injection control unit