A complete circuit.

Open Circuits
An open circuit is an incomplete circuit. An open circuit occurs when some kind of fault or failure interrupts the circuit path and prevents current
flow. Some common causes of open circuits are:

-

broken wire

-

loose or disconnected connector

-

loose or damaged connector terminal

-

corrosion

-

failed fuse or component

Test for an open circuit by checking continuity using an ohmmeter (multimeter), or by checking for voltage at various points of the circuit using a
test light or voltmeter (multimeter).  See: Checking Wiring and Components

Short Circuits
A short circuit is an unintended complete circuit. A short circuit occurs when some kind of fault or failure causes current flow to follow the wrong
path.

A short circuit to ground (grounded circuit) may prevent voltage from reaching a component. If voltage is shorted directly to ground, bypassing
any load, the unrestricted current flow will damage fuses, wires or components. Some common causes of short circuits are:

-

damaged wire or wiring harness

-

faulty insulation

-

internally damaged component

-

incorrect connection

Test for a short circuit to ground using a multimeter or a test light to indicate circuit faults and abnormal current flow paths.  See: Checking For
Short Circuit to Ground