audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

All Technical Service Bulletins for Vacuum Pump:|5790T03|Page 8048 > < Customer Interest for Vacuum Pump:|5790T03|Page 8045
Page 1
background image

Vacuum Pump: All Technical Service Bulletins
Power Door Lock System - Does Not Work

57-90-T03 Jan 90

Power Door Lock System - Inoperative

Cause:

Vacuum leak at "T" fitting under driver's seat. Vacuum hose disconnected (see illustration).

Production:

Position and length of vacuum hose changed.

As of:

March 1988
VIN:

89_JA322898

Installation procedure of vacuum hose changed.

As of:

August 1988
VIN:

89_KA039563

Service:

Reconnect loose vacuum hose.

80/90 All M.Y. 1988-89

All Technical Service Bulletins for Vacuum Pump:|5790T03|Page 8048 > < Customer Interest for Vacuum Pump:|5790T03|Page 8045