Workshop Manuals Factory service & repair Audi
01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Audi 90CS Quattro V6-2.8L (AFC) (1995)03 · Maintenance
03 · Maintenance

Refrigerant: Specifications (page 4 of 4)

Make
Audi
Model
90 CS Quattro
Engine
V6-2.8L (AFC)
Year
1995
Section
Fluids › Refrigerant
MaintenanceSpecifications · page 4 of 4
background image

Refrigerant: Service and Repair

    Automotive refrigerant containing CFC's is hazardous to the earth's atmosphere. To protect our environment, use an Underwriter's
Laboratory (UL) approved refrigerant recovery/recycling unit such as Kent-Moore ACR3 or equivalent, whenever discharging an A/C system.
    The A/C system should be serviced only by trained personnel familiar with equipment use, related safety precautions and regulations
governing the discharging/handling/disposal of automotive refrigerants.
    Always wear safety goggles when charging or discharging system. Use caution so that refrigerant does not come in contact with your skin or
eyes. If refrigerant comes in contact with skin or eyes, do not rub, flush immediately with cool water, then seek medical attention. Keep
refrigerant away from open flames, exposure to open flame will produce poisonous gas.

1.

Close both valves on A/C manifold gauge set, then connect hose from low pressure gauge to low pressure service valve on compressor.

2.

Remove A/C refrigerant high pressure switch (red housing) in A/C line between condenser and compressor.

3.

Connect hose from high pressure gauge to high pressure service valve located in A/C line between condenser and compressor, then the manifold
gauge hose to inlet connection on refrigerant recovery/recycling unit.

4.

Follow refrigerant recovery/recycling unit manufacturer's instructions to discharge A/C system into recovery/recycling unit.

5.

Close manifold gauge valves when refrigerant is fully discharged.

6.

Disconnect power supply from compressor clutch to prevent damage to system if compressor is accidentally switched On with refrigerant system
discharged.

Pinch or Ctrl + scroll to zoom. Double-tap to reset.

Parts & tools for this job For 1995 Audi 90 2.8L

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.