| Switch on the air conditioner at the operating unit as follows: |
l
| Set the rotary temperature control -1- to the
„Cold“ stop. |
l
| Set the rotary air distribution control -3- to
„Dash panel vents“. |
l
| Air conditioner compressor on - lamp in AC button -4- lights. |
l
| Air recirculation mode on - lamp in Air recirculation button -5- lights. |
l
| Set the rotary fresh air blower control -2- to speed
„4“. |
–
| Check the display in the display zones: |
l
| The current calculated by the air conditioning system control unit -J301- flowing via the air conditioner compressor regulating valve -N280- is displayed as being greater than 0.3 A (air conditioner compressor switched on). |
l
| The pressure displayed rises above the value with the air conditioner compressor switched off. |
Note t
| If the pressure displayed does not change and actuation of the air conditioner compressor is OK, check again whether the calculated current is actually flowing via the air conditioner compressor regulating valve -N280- and whether the air conditioner compressor is actually being driven. If the current is actually flowing via -N280- and the air conditioner compressor is being driven, there is a fault in the refrigerant circuit. The vehicle is to be taken to a workshop equipped with the necessary tools where the work can be performed by appropriately qualified personnel → Air conditioner with refrigerant R134a (there may be problems with air conditioner compressor control). Inform the workshop of the problem detected. |
t
| The air conditioner compressor regulating valve -N280- is actuated by the air conditioning system control unit -J301- such that the temperature of the air downstream of the evaporator reaches the specified value (approx. 2 to 5 °C). |
t
| After starting the vehicle, a value greater than 0.55 A is displayed for actuation of the air conditioner compressor regulating valve -N280- depending on the measured temperature, engine speed and electrical system voltage. As soon as the temperature measured by the evaporator output temperature sender -G263- approaches the specified value, actuation is cancelled and the air conditioner compressor output thus reduced. |
t
| Under certain operating conditions, residual moisture in the refrigerant circuit may lead to the formation of ice at the air conditioner compressor regulating valve -N280- (and at the expansion valve). Such ice formation impedes air conditioner compressor control. The evaporator is excessively cooled and ices up. Icing-up of the evaporator may give rise to various problems → Chapter. |
t
| If no or an insufficient current is displayed in the measured value block for actuation of the air conditioner compressor regulating valve -N280-, check actuation of -N280- → Chapter. |
|
|
|