A1
General view of components |
HD = High-pressure side |
ND = Low-pressure side |
1 - | Air conditioner compressor regulating valve -N280- |
q | Checking actuation of -N280- → Chapter1) |
2 - | Air conditioner compressor |
q | Detaching from holder/re-attaching → Chapter1) |
3 - | High-pressure safety valve |
4 - | Oil drain plug |
5 - | Cap |
q | With seal |
q | Always to be screwed on |
6 - | Service connection on low-pressure end |
q | For measurement and drainage |
Caution
|
7 - | Evaporator |
8 - | Expansion valve |
9 - | High-pressure sender -G65-1) |
q | Checking pressure signal → Chapter |
q | Removing and installing → Chapter |
10 - | Connection with valve |
11 - | Condenser |
12 - | Receiver |
q | The receiver is integrated into the condenser |
13 - | Service connection on high-pressure end |
q | For measurement, drainage and filling |
Caution
|
14 - | Cap |
q | With seal |
q | Always to be screwed on |
15 - | Pulley 1) |
q | Replacing → Chapter |
q | The pulley cannot be replaced separately at present on „Delphi“ air conditioner compressors |