audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Exploded view - selector forks > < Removing and installing angled rod
Renewing oil seal for selector mechanism in gearbox
Renewing oil seal for selector mechanism in gearbox
Special tools and workshop equipment required
   
t  Tube -VW 423-
  W00-0140
t  Extractor tool -T20143/1-
  W00-2958
Procedure
–  Remove air cleaner housing → Injection and ignition system; Rep. gr.24.
  A24-10842
–  Remove securing clip -1-.
–  Detach gear selector cable from gearbox selector lever -B-.
–  Remove gate relay lever -A- from gearbox together with cable end-piece → Fig..
–  Remove gearbox selector lever -B- by removing nut -arrow 2-.
  N34-11183
–  Pry out oil seal using extractor tool -T20143/1-.
  A34-0612
–  Drive in oil seal using tube -VW 423-.
The remaining installation steps are carried out in reverse sequence; note the following:
–  Install gearbox selector lever and gate relay lever → Chapter.
  Note
The gearbox selector lever can only be installed in one position.
–  Install air cleaner housing → Injection and ignition system; Rep. gr.24.
Tightening torque → Chapter
  A34-0315

Exploded view - selector forks > < Removing and installing angled rod