audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Housing for thermostat with rear coolant pipe - exploded view > < Removing and installing coolant pump
Removing and installing coolant circulation pumpV50
Removing and installing coolant circulation pump -V50-
Special tools and workshop equipment required
   
t  Hose clamps for hoses up to 25 mm -3094-
  W00-0079
t  Hose clip pliers -VAS 6362-
  W00-10427
Removing
–  Unplug electrical connector -1-.
–  Remove bolt -3- and detach coolant circulation pump -V50- from retainer.
–  Clamp off coolant hoses -2- using hose clamps, up to 25 mm -3094- and detach from coolant circulation pump -V50-.
Installing
Installation is carried out in the reverse order; note the following:
l  Tightening torques → Chapter „Coolant pump - exploded view“
  Note
Secure all hose connections with the correct type of hose clips (same as original equipment) → Electronic parts catalogue.
–  Check coolant level → Anchor.
  N19-10376

Housing for thermostat with rear coolant pipe - exploded view > < Removing and installing coolant pump