| Unplug electrical connector -4- for Lambda probe after catalytic converter -G130- and Lambda probe heater -Z19-. |
–
| Unscrew Lambda probe after catalytic converter -G130--2- using tool from Lambda probe open ring spanner set -3337-. |
When installing, note the following: |
Note t
| Threads of new Lambda probes are already coated with assembly paste; the paste must not get into the slots on the probe body. |
t
| In the case of a used Lambda probe grease only the thread with high-temperature paste. The paste must not get into the slots on the Lambda probe body. High-temperature paste → Parts catalogue |
t
| When installing, the Lambda probe wire must always be reattached at the same locations to prevent it from coming into contact with the exhaust pipe. |
l
| Tightening torque: Lambda probe - overview → Chapter |
|
|
|