| Turn air filter element in anti-clockwise direction -arrow A- and detach it. |
To ensure that the air mass meter -G70- functions properly, it is important to observe the following notes and instructions. |
Note t
| If the air filter element is very dirty or wet, dirt or water could reach the air mass meter and affect the air mass value. This would lead to loss of power, since a smaller injection quantity is calculated. |
t
| Always use genuine part for air filter element. |
t
| The air cleaner housing MUST be clean. |
t
| Hose connections and air pipes and hoses must be free of oil and grease before assembly. |
t
| Use a silicone-free lubricant when installing the air hoses. |
t
| To prevent malfunctions, cover critical parts of the engine air intake (air mass meter, air pipes, etc.) with a clean cloth when blowing out the air cleaner housing with compressed air. |
t
| Observe environmental requirements for disposal. |
|
|
|