Fault table for convenience system
Fault table; fault code 01317 - 01701
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01330
|
|
|
Convenience system central control unit -J393
|
|
|
|
Power supply too low Power supply too high
|
- Fuses defective - Battery -A defective or discharged - Alternator -C defective - Voltage regulator -C1 defective
|
- Check fuses and replace if necessary Check supply voltage. Read measured value block; display group 016 , Display zone 1
|
|
Defective
|
- Convenience system central control unit -J393 defective
|
- Replace convenience system central control unit -J393
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01331
|
|
|
Door control unit, driver's side -J386
|
|
|
|
No communication
|
- Short or open circuit in the connectors or in both Group convenience data bus wires
|
- Check connectors and data bus wires in the Group convenience data bus in accordance with the current flow diagrams and repair if necessary. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 017 => Page 01-64, Display zone 1; check communication to door control unit
|
|
|
- Door control unit in emergency running mode
|
- Interrogate control unit version . If the door control unit no longer responds, check the door control unit and replace if necessary
|
|
Power supply too low Power supply too high
|
- Battery -A defective or discharged - Alternator -C defective - Voltage regulator -C1 defective
|
- Check supply voltage. Read measured value block; display group 016 => Page 01-63, Display zone 1
|
|
Defective
|
- Door control unit, driver's side defective -J386
|
- Replace door control unit, driver's side -J386
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01332
|
|
|
Door control unit, passenger's side -J387
|
|
|
|
No communication
|
- Short or open circuit in the connectors or in both Group convenience data bus wires
|
- Check connectors and data bus wires in the Group convenience data bus in accordance with the current flow diagrams and repair if necessary. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 017 => Page 01-64, Display zone 2; check communication to door control unit
|
|
|
- Door control unit in emergency running mode
|
- Interrogate control unit version . If the door control unit no longer responds, check the door control unit and replace if necessary
|
|
Power supply too low Power supply too high
|
- Battery -A defective or discharged - Alternator -C defective - Voltage regulator -C1 defective
|
- Check supply voltage. Read measured value block; display group 016 => Page 01-63, Display zone 1
|
|
Defective
|
- Door control unit, passenger's side -J387 defective
|
- Replace door control unit, passenger's side -J387
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01333
|
|
|
Door control unit, RL -J388
|
|
|
|
No communication
|
- Short or open circuit in the connectors or in both Group convenience data bus wires
|
- Check connectors and data bus wires in the Group convenience data bus in accordance with the current flow diagrams and repair if necessary. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 017 => Page 01-64, Display zone 3; check communication to door control unit
|
|
|
- Door control unit in emergency running mode
|
- Interrogate control unit version . If the door control unit no longer responds, check the door control unit and replace if necessary
|
|
Power supply too low Power supply too high
|
- Battery -A defective or discharged - Alternator -C defective - Voltage regulator -C1 defective
|
- Check supply voltage. Read measured value block; display group 016 => Page 01-63, Display zone 1
|
|
Defective
|
- Door control unit, rear left -J388 defective
|
- Replace door control unit, rear left -J388
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01334
|
|
|
Door control unit RR -J389
|
|
|
|
No communication
|
- Short or open circuit in the connectors or in both Group convenience data bus wires
|
- Check connectors and data bus wires in the Group convenience data bus in accordance with the current flow diagrams and repair if necessary. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 017 => Page 01-64, Display zone 4; check communication to door control unit
|
|
|
- Door control unit in emergency running mode
|
- Interrogate control unit version . If the door control unit no longer responds, check the door control unit and replace if necessary
|
|
Power supply too low Power supply too high
|
- Battery -A defective or discharged - Alternator -C defective - Voltage regulator -C1 defective
|
- Check supply voltage. Read measured value block; display group 016 => Page 01-63, Display zone 1
|
|
Defective
|
- Door control unit, rear right -J389 defective
|
- Replace door control unit, rear right -J389
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01336
|
|
|
CAN convenience
|
|
|
|
In 1-wire operation
|
- Short or open circuit in the connectors or in one of the two Group convenience data bus wires - Data bus only operating on one wire (possibility of EMC problems)
|
- Check connectors and data bus wires in the Group convenience data bus in accordance with the current flow diagrams and repair if necessary. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Read measured value block; display group 016 => Page 01-85
|
|
Defective
|
- Short or open circuit in the connectors or in both Group convenience data bus wires
|
- Check connectors and data bus wires in the Group convenience data bus in accordance with the current flow diagrams and repair if necessary. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Check data exchange => Page 01-85
|
1) Is set if operated for longer than 1 minute (switch stuck).
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01348
|
|
|
Warning lamp for interior monitoring deactivation -K162
|
|
|
|
Short to positive
|
- Fault in wiring or connectors - Warning lamp for interior monitoring deactivation -K162 defective
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder Check and if necessary replace warning lamp for interior monitoring deactivation -K162
|
01357
|
|
|
Motor for tank flap locking -V155
|
|
|
|
Short to positive Short to earth
|
- Fuses defective - Fault in wiring or connectors - Motor for tank flap locking -V155 defective
|
- Check fuses and replace if necessary
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01366
|
|
|
Opening via crash signal
|
|
|
|
|
- Final control diagnosis on airbag control unit -J234 has been performed - Airbag control unit -J234 triggered by crash situation
|
- Read fault memory of airbag control unit -J234 Erasing fault memory => Page 01-37
|
|
Open circuit
|
- Short or open circuit in the wiring connection between the airbag control unit -J234 and the convenience system central control unit -J393
|
- Check wiring connection between the airbag control unit -J234 the and convenience system central control unit -J393 according to current flow diagram and repair if necessary => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
01368
|
|
|
Alarm from luggage compartment switch -F206
|
|
|
|
|
- Anti-theft alarm has triggered as a result of unauthorised opening of the tailgate - Contact switch in tailgate -F206 defective - False alarm
|
- Erasing fault memory => Page
|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01369
|
|
|
Alarm from bonnet switch -F120
|
|
|
|
|
- Anti theft alarm has triggered as a result of unauthorised opening of the bonnet - Switch bonnet lid -F120 defective - False alarm
|
- Erasing fault memory => Page
|
01370
|
|
|
Alarm from interior monitoring
|
|
|
|
|
- Anti-theft alarm has triggered as a result of interior monitoring - False alarm
|
- Read out interior monitoring fault memory Fault-finding after self-diagnosis ultrasonic interior monitoring=> Page 01-37
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01371
|
|
|
Alarm triggered by driver's door contact switch -F2
|
|
|
|
|
- Anti-theft alarm has triggered as a result of unauthorised opening of driver's door - Door contact switch -F2 defective - False alarm
|
- Erasing fault memory => Page
|
01373
|
|
|
Alarm from radio earth contact
|
|
|
|
|
- Anti-theft alarm has triggered as a result of unauthorised removal of radio - Open circuit in radio earth connection - False alarm
|
- Erasing fault memory => Page 01-37 Restore earth connection to radio => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01374
|
|
|
Alarm from terminal 15
|
|
|
|
|
- Anti-theft alarm has been triggered by unauthorised starting (short circuiting) - Short-circuit between terminal 30 and terminal 15 - False alarm
|
- Erasing fault memory => Page 01-37 Check and if necessary repair wiring and connections according to the current flow diagram. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
01379
|
|
|
Switch for interior monitoring -E183
|
|
|
|
Implausible signal
|
- Fault in wiring or connectors
|
- Check and if necessary repair wiring and connections according to the current flow diagram. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
|
- Switch for interior monitoring -E183 defective
|
- Check switch for interior monitoring -E183 and replace if necessary
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01384
|
|
|
Alarm from rear window glass-break sensor -G304
|
|
|
|
|
- The anti-theft alarm has been triggered by an attempted break-in at the rear window - Conductor loop of the rear window glass-break sensor -G304 is interrupted, is not correctly connected. - False alarm - Short or open circuit in the wiring/connectors between the rear window glass-break sensor -G304 and the convenience system central control unit -J393
|
- Erasing fault memory => Page
|
01398
|
|
|
Signal wiring from CL: Doors open
|
|
|
|
Short to positive
|
- Fault in wiring or connectors
|
- Check and if necessary repair wiring and connections according to the current flow diagram. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01403
|
|
|
Rear window glass-break sensor -G304
|
|
|
|
|
- When activating the anti-theft alarm, there is/was a short or open circuit in the wiring/connectors between the rear window glass-break sensor -G304 and the convenience system central control unit -J393 - When activating the anti-theft alarm, the conductor loop of the rear window glass-break sensor is/was interrupted or incorrectly connected
|
- Erasing fault memory => Page
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01559
|
|
|
Driver's door
|
|
|
|
Does not lock Does not unlock
Does not deadlock Deadlock does not release
|
- Fault in wiring or connectors - No voltage supply to the driver's door - Driver's side CL lock units defective
|
- Check and if necessary repair wiring and connections according to the current flow diagram.
|
|
Defective
|
- Door control unit -J386, driver's side defective
|
- Check driver's side door control unit -J386 and repair if necessary
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01560
|
|
|
Passenger's door.
|
|
|
|
Does not lock Does not unlock
Does not deadlock Deadlock does not release
|
- Fault in wiring or connectors - No voltage supply to the passenger's door - Passenger's side CL lock units defective
|
- Check and if necessary repair wiring and connections according to the current flow diagram.
|
|
Defective
|
- Door control unit -J387, passenger's side defective
|
- Check passenger's side door control unit -J387 and repair if necessary
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01561
|
|
|
Door rear left
|
|
|
|
Does not lock Does not unlock
Does not deadlock Deadlock does not release
|
- Fault in wiring or connectors - No voltage supply to the rear left door1) - Rear left door CL lock unit defective
|
- Check wiring and connectors according to current flow diagram
|
|
Defective
|
- Rear left door control unit defective1) - Convenience system central control unit -J393 defective2)
|
- Check rear left door control unit and replace if necessary1) Check convenience system central control unit -J393 and replace if necessary2)
|
1) For equipment version with rear electric window lifters only.
2) In the case of mechanical rear window lifters, the CL functions for the rear doors are controlled via the convenience system central control unit.
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01562
|
|
|
Door, rear right
|
|
|
|
Does not lock Does not unlock
Does not deadlock Deadlock does not release
|
- Fault in wiring or connectors - No voltage supply to the rear right door1) - Rear right door CL lock unit defective
|
- Check wiring and connectors according to current flow diagram
|
|
Defective
|
- Rear right door control unit defective1) - Convenience system central control unit -J393 defective2)
|
- Check rear right door control unit and replace if necessary1) Check convenience system central control unit -J393 and replace if necessary2)
|
1) For equipment version with rear electric window lifters only.
2) In the case of mechanical rear window lifters, the CL functions for the rear doors are controlled via the convenience system central control unit.
1) Is set if operated for longer than 1 minute (switch stuck).
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01565
|
|
|
Luggage compartment light -W3
|
|
|
|
Short to positive Short to earth Open circuit
|
- Fault in wiring or connectors - Luggage compartment light -W3 defective
|
- Check wiring and connectors according to current flow diagram
|
01568
|
|
|
Signal for automatic opening
|
|
|
|
Short to positive
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
01569
|
|
|
Signal for automatic closing
|
|
|
|
Short to positive
|
- Fault in wiring or connectors
|
- Check wiring and connectors according to current flow diagram => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01572
|
|
|
Alarm from door contact switch, passenger's side -F3
|
|
|
|
|
- Anti-theft alarm has triggered as a result of unauthorised opening of the passenger's door - Door contact switch -F3 defective - False alarm
|
- Erasing fault memory => Page
|
01573
|
|
|
Alarm from rear left door contact switch -F10
|
|
|
|
|
- Anti-theft alarm has triggered as a result of unauthorised opening of rear left door - Door contact switch -F10 defective - False alarm
|
- Erasing fault memory => Page
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01574
|
|
|
Alarm from RR door contact switch -F11
|
|
|
|
|
- Anti-theft alarm has triggered as a result of unauthorised opening of rear right door - Door contact switch -F11 defective - False alarm.
|
- Erasing fault memory => Page
|
01615
|
|
|
Switch for remote release fuel filler flap -E204
|
|
|
|
Implausible signal 1)
|
- Fault in wiring or connectors - Switch for remote release fuel filler flap -E204 defective
|
- Check wiring and connectors according to current flow diagram
|
1) Is set if operated for longer than 1 minute (switch stuck)
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01616
|
|
|
Signal wire to interior monitoring
|
|
|
|
Short to positive Short to earth
|
- Fault in wiring or connectors
|
- Check and if necessary repair wiring and connections according to the current flow diagram. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
No communication
|
- Open circuit in wiring or in connectors between the transmit/receive module for interior monitoring -G303 and the convenience system central control unit -J393 - Transmit/receive module for interior monitoring -G303 defective
|
- Read out interior monitoring fault memory Check wiring and connectors between the transmit/receive module for interior monitoring -G303 the and convenience system central control unit -J393 according to current flow diagram and repair if necessary => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|
Read out fault memory
|
- Interior monitoring self test has not been completed OK
|
- Read fault memory of interior monitoring Fault-finding after self-diagnosis ultrasonic interior monitoring=> Page 01-143
|
|
---|
Output on printer V.A.G 1551
|
Possible causes of fault
|
Fault remedy
|
01699
|
|
|
Motor for CL, tailgate -V53
|
|
|
|
Short to positive Short to earth
|
- Fault in wiring or connectors - Motor for CL, tailgate -V53 defective
|
- Check fuses and replace if necessary
|
01701
|
|
|
Dimming for interior light
|
|
|
|
Short to positive
|
- Defective wiring or connectors between the central control unit an the front or rear interior lamp
|
- Check and if necessary repair wiring and connections according to the current flow diagram. => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
|