audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Diversion of fuel (for the additional heater) from the fuel tank > < Checking electric additional heater actuation by the engine control unit
Additional heater
Diversion of fuel for additional heater
Diversion of fuel for additional heater
 
A82-0241

Notes:

  • ◆ For the operation of the additional heater it is necessary:
    • ‒ the fuel line must be flush with the bottom of the vehicle, and routed so that they are protected from mechanical damage.
    • ‒ for the fuel line to the additional heater to be protected from heat generation that could impair operation.
    • ‒ the fuel line must not touch hot vehicle components.
 
A82-0241
  • Connection for diversion of fuel for additional heater
    • ◆ Fuel diversion from the fuel tank

Notes:

  • ◆ Varying fuel tank designs for vehicles equipped with an electrical vs. a fuel-powered additional heater
  • ◆ The connection for diverting fuel for the additional heater is only present on vehicles with a diesel engine and a fuel-powered additional heater.

=> Relevant Workshop Manual, Fuel Supply

 
A82-0241
  • Metering pump -V54
    • ◆ Removing and installing
    • ◆ Check fuel delivery
    • ◆ Check actuation => Page 01-41
  • Additional heater

Diversion of fuel (for the additional heater) from the fuel tank > < Checking electric additional heater actuation by the engine control unit