→ Display on VAS 5051:
-
◆ Display zone -1- displays which control element is currently being actuated (e.g. 1st control element in the test).
-
◆ The control elements which are currently actuated or have been actuated are listed in display zone -2-. The control element which is currently actuated is in the bottom line.
-
‒ Press the ⇒key to switch to the next component. Function and sequence =>Table of final controls actuated, Page 01-44
Notes:
-
◆ By pressing the ←key you will return to the selection program.
-
◆ Final control diagnosis can be terminated by pressing the C key.
-
◆ Interrogating fault memory on completion of final control diagnosis => Page 01-24
-
◆ On termination of the final control diagnosis, interrogate the fault memory => Page 01-67
Final controls actuated
|
---|
Indicated on display
|
Desired function
|
Fault remedy
|
Glow plug with flame detector -Q8
|
Glow plug actuated for 60 seconds. Reading on multimeter V.A.G 1715 increases by 4 to 10 A during actuation of -Q8.
|
- Check wiring between -Q8 and -J162. Check additional heater electrical components
|
Press⇒key
|
|
|
Notes:
-
◆ Any fault at the glow plug with flame detector -Q8 is stored in the fault memory.
-
◆ The current consumed by the glow plug is restricted by the control unit such that the power at the glow plug is approx. 96 W (current level varies with battery voltage).
|
---|
Indicated on display
|
Desired function
|
Fault remedy
|
Metering pump -V54
|
Metering pump actuated for 10 seconds. Clocking can be heard in the vicinity of metering pump.
|
- Check wiring between -V54 and -J162. Check additional heater electrical components
|
Press⇒key
|
|
|
Notes:
-
◆ The metering pump is installed on the floor panel in the right rear wheel area.
-
◆ On vehicles with diesel engines, allowance is made in the on-board computer consumption display for the fuel consumption to the additional heater. This function is implemented by the engine control unit, however, only when the engine is running (metering pump -V54 and engine control unit are connected by a wire).
-
◆ During actuation of the -V54 metering pump, approx. 4 cm3 of fuel are pumped into the additional heater. If the final control diagnosis is performed several times in sequence, then smoke may develop upon initial operation.
|
---|
Indicated on display
|
Desired function
|
Fault remedy
|
Combustion air blower -V6
|
Combustion air blower -V6 actuated for 30 seconds. Running noise can be heard in vicinity of additional heater.
|
- Check wiring between -V6 and -J162. Check additional heater electrical components
|
Press ⇒key
|
|
|
Final control diagnosis is completed (for additional heaters without recirculating pump).
|
|
Notes:
-
◆ On vehicles without -V55 recirculating pump the control element "-V55 recirculating pump" is displayed, check the coding of the additional heater=> Page 01-61
-
◆ On vehicles with additional heater without recirculating pump -V55 actuation of -V6 combustion air blower terminates final control diagnosis.
-
◆ The Audi A2 currently has no -V55 recirculating pump for the additional heater installed.
|
---|
Indicated on display
|
Desired function
|
Fault remedy
|
Recirculating pump -V55 At present, installation of a recirculating pump is not envisaged
|
Recirculating pump -V55 actuated for 30 seconds. Running noise can be heard in vicinity of additional heater.
|
- Check wiring between -V55 and -J162. Check additional heater electrical components
|
Press ⇒key
|
|
|
Control element test is completed
|
|
Notes:
-
◆ If on vehicles without -V55 recirculating pump, the control element "-V55 recirculating pump" is displayed, check the coding of the additional heater=> Page 01-61
-
◆ On vehicles with additional heater with -V55 recirculating pump actuation of the -V55 recirculating pump terminates final control diagnosis.
-
◆ The Audi A2 currently has no -V55 recirculating pump for the additional heater installed.
|
---|
Indicated on display
|
Desired function
|
Fault remedy
|
Fresh air blower actuation signal Provided for the auxiliary/additional heater version
|
Air conditioner operating and display unit -E87 starts up for 30 seconds. Fresh-air blower -V2 is actuated for 30 seconds by -E87.
|
- Check wiring between -E87 and -J162. Check additional heater electrical components
|
Press ⇒key
|
|
|
Control element test is completed
|
|
Notes:
-
◆ If on the Audi A2 the control element "Fresh air blower actuation signal" is displayed, check the coding of the additional heater=> Page 01-61
-
◆ For the additional heater the signal for actuating the fresh-air blower is not output (additional heater only operates when engine is running).
-
◆ The signal for fresh air blower actuation is intended for the version with auxiliary heater. At present, it installation of an auxiliary heater in the Audi A2 is not envisaged.
|