→ Display on VAS 5051:
-
◆ The number of faults stored appears in display zone -1-.
-
◆ The fault code, the fault location and the type of fault stored appear in display zone -2-.
Notes:
-
◆ By pressing the ←key you will return to the selection program.
-
◆ If a fault was detected:
-
‒ 1. Rectify fault.
-
‒ 2. Interrogate fault memory (function 02).
-
‒ 3. Erase fault memory (function 05).
-
‒ 4. Check code (function 01) or encode control unit (function 07).
-
‒ 5. End output (function 06).
-
◆ If no fault was detected but the additional heater is not working properly (e.g. additional heater does not start, insufficient heat output):
-
‒ 1. Read measured value block (function 08).
-
‒ 2. Perform final control diagnosis (function 03)=> Page 01-41.
-
‒ 3. Check additional heater function .
Notes:
-
◆ As of model year 2001 additional heaters with a -J162 heater control unit and a software version starting from "D50" are used.
-
◆ If on additional heaters with a -J162 heater control unit and a software version as of "D50", the additional heater does not begin to operate if contact "3" of the 6-pin connector is connected to earth (additional heater actuation) check the adaption in the -J162 control unit adaption channel "10" and correct it as necessary .
|