| Install the restrictor -B- on the correct side (with the arrow on the restrictor pointing towards the evaporator). |
t
| Check that the restrictor is correctly seated, fitted tightly in the refrigerant pipe. |
–
| Check that the O-ring seal -C- (7.5 mm; 1.5 mm) is correctly seated in the groove. |
–
| Replace the O-ring seal -D- (11.1 mm; 1.8 mm). |
–
| Apply a small amount of refrigerant oil to the O-ring seal in the restrictor |
–
| Install the refrigerant pipes such that they are not strained. |
–
| Tighten the screw connection -A- to 15 Nm. |
|
|
|