Evaluating measured value blocks, display groups 0...6 -Basic functions-
Evaluating measured value blocks, display groups 0...6 -Basic functions-
|
Display group 1 -Basic functions-
|
|
Read measured value block 1
|
⇒
|
◂ Indicated on display
|
|
|
|
xxxx rpm
|
xx.x °C
|
xx.x %
|
xxxxxxxx
|
|
|
|
|
1
|
2
|
3
|
4
|
◂ Display zones
|
Specification
|
Evaluation
|
|
|
|
|
|
Adjustment conditions
|
10111111
|
|
|
|
|
|
Lambda regulation values
|
-15...15 %
|
=> Page 01-114
|
|
|
|
Coolant temperature
|
75...85 °C
|
=> Page 01-101
|
|
|
Engine speed (idling speed)
|
630...830 rpm1)
|
=> Page 01-100
|
1) Up-to-date specifications:
=> Exhaust emissions test binder
Significance of 8-digit number block
|
|
|---|
|
Significance if display = 1
|
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
Significance
|
|
|
|
|
|
|
|
|
1
|
Coolant temperature above 80 °C
|
|
|
|
|
|
|
|
1
|
|
Speed below 2000 rpm
|
|
|
|
|
|
|
1
|
|
|
Throttle valve closed
|
|
|
|
|
|
1
|
|
|
|
Lambda regulation OK.
|
|
|
|
|
1
|
|
|
|
|
Idling switch closed
|
|
|
|
1
|
|
|
|
|
|
Air conditioner compressor switched off
|
|
|
1
|
|
|
|
|
|
|
Catalytic converter hot (over 300 °C)
|
|
1
|
|
|
|
|
|
|
|
No faults recognised by self-diagnosis
|
Evaluating display group 1, display zone 1 - Engine speed (idling speed)
|
Appears on display
|
Possible fault cause
|
Fault elimination
|
|
Less than specification
|
- Throttle valve control part sticking or defective
|
- Check throttle valve control part => Page 24-49
|
|
|
- Air filter element obstructed by dirt
|
- Renew air filter element
|
|
Greater than specification
|
- Throttle valve control part sticking or defective
|
- Interrogate fault memory, => Page 01-19
|
|
|
- Large amount of unmetered air (cannot be compensated for by the idling stabilisation)
|
- Check intake air system for leaks => Page 24-93
|
|
|
|
- Check throttle valve control part => Page 24-49
|
|
|
|
- Perform idling check => Page 24-96
|
Evaluating display group 1, display zone 2 - Coolant temperature
|
Appears on display
|
Possible fault cause
|
Fault elimination
|
|
Less than 80 °C
|
- Engine too cold
|
- If necessary carry out test drive
|
|
|
- Coolant temperature sender or wiring to engine control unit
|
- Check coolant temperature sender
|
|
|
- Thermostat defective
|
- Check thermostat => Repair group 19; Removing and installing parts of cooling system; Parts of cooling system engine side
|
|
More than 110 °C
|
- Radiator soiled
|
- Clean radiator
|
|
|
- Radiator fan not functioning
|
- Check function
|
|
|
- Thermostat defective
|
- Check thermostat => Repair group 19; Removing and installing parts of cooling system; Parts of cooling system
|
|
|
- Coolant temperature sender or wiring to engine control unit
|
- Check coolant temperature sender
|
|
Display group 2 -Basic functions-
|
|
▪ Engine running at idling speed
|
|
Read measured value block 2
|
⇒
|
◂ Indicated on display
|
|
|
|
xxxx rpm
|
xxx.x %
|
x.x ms
|
xxx mbar
|
|
|
|
|
1
|
2
|
3
|
4
|
◂ Display zones
|
Specification
|
Evaluation
|
|
|
|
|
|
Intake manifold pressure
|
290...360 mbar
|
=> Page 01-104
|
|
|
|
|
Injection period
|
2.0...4.0 ms
|
=> Page 01-103
|
|
|
|
Engine load
|
12...18 %
|
=> Page 01-113
|
|
|
Engine speed (idling speed)
|
630...830 rpm1)
|
=> Page 01-100
|
1) Up-to-date specifications:
=> Exhaust emissions test binder
Evaluating display group 2, display zone 3 - Injection period
|
Appears on display
|
Possible fault cause
|
Fault elimination
|
|
Less than 2.0 ms
|
- Large amount of fuel from the activated charcoal filter system
|
- Check activated charcoal filter solenoid valve 1 => Page 01-72, Final control diagnosis
|
|
|
- Incorrect injectors with greater throughput installed
|
- Check injectors => Page 24-78
|
|
|
|
- Check injector part number: => Parts micro-fiche
|
|
More than 4.0 ms
|
- Increased engine load due to electric consumers, air conditioner, gear selected or P.A.S. on full lock
|
- Eliminate increased load (air conditioner, power assisted steering etc.)
|
|
|
- Incorrect injectors with smaller throughput installed
|
- Check injectors => Page 24-78
|
|
|
|
- Check injector part number: => Parts micro-fiche
|
Evaluating display group 2, display zone 4 - Intake manifold pressure
|
Appears on display
|
Possible fault cause
|
Fault elimination
|
|
Less than 290 mbar
|
- Large amount of unmetered air (air leak) between intake manifold and air cleaner
|
- Rectify air leak
|
|
More than 360 mbar
|
- Gear selected (automatic gearbox)
|
- Place selector lever in P or N
|
|
|
- Engine loaded due to ancillaries
|
- Eliminate load (air conditioner, power-assisted steering etc.)
|
|
|
- Air filter element obstructed by dirt
|
- Renew air filter element
|
|
Display group 3 -Basic functions-
|
|
▪ Engine running at idling speed
|
|
Read measured value block 3
|
⇒
|
◂ Indicated on display
|
|
|
|
xxxx rpm
|
xxx mbar
|
xx°
|
xx.x°BTDC
|
|
|
|
|
1
|
2
|
3
|
4
|
◂ Display zones
|
Specification
|
Evaluation
|
|
|
|
|
|
Ignition timing
|
0...8 ° BTDC
|
---
|
|
|
|
|
Throttle valve angle (potentiometer 1 -G187)
|
1...5 °
|
=> Page 01-114
|
|
|
|
Intake manifold pressure
|
290...360 mbar
|
=> Page 01-104
|
|
|
Engine speed (idling speed)
|
630...830 rpm1)
|
=> Page 01-100
|
1) Up-to-date specifications:
=> Exhaust emissions test binder
|
Display group 4 -Basic functions-
|
|
▪ Engine running at idling speed
|
|
Read measured value block 4
|
⇒
|
◂ Indicated on display
|
|
|
|
xxxx rpm
|
xx.xxx V
|
xxx.x °C
|
xxx.x °C
|
|
|
|
|
1
|
2
|
3
|
4
|
◂ Display zones
|
Specification
|
Evaluation
|
|
|
|
|
|
Intake air temperature
|
-10...50 °C
|
=> Page 01-109
|
|
|
|
|
Coolant temperature
|
75...85 °C
|
=> Page 01-108
|
|
|
|
Voltage supply for engine control unit
|
12.5...14.5 V
|
=> Page 01-107
|
|
|
Engine speed (idling speed)
|
630...830 rpm1)
|
=> Page 01-100
|
1) Up-to-date specifications:
=> Exhaust emissions test binder
Note on display zone 3:
The engine control unit will use the intake air temperature as a replacement value for an engine start (start temperature - replacement value) as soon as there is a fault stored in the fault memory, which affects the coolant temperature sender (G62). The temperature then rises according to a model stored in the control unit. When the engine has reached normal working temperature a fixed replacement value will be displayed after a certain period. This fixed value is also dependent upon the intake air temperature.
Note on display zone 4:
The total temperature range is given as the specification. The displayed value must be above ambient temperature.
Evaluating display group 4, display zone 2 - Control unit voltage supply
|
Appears on display
|
Possible fault cause
|
Fault elimination
|
|
Less than 12.500 V
|
- Alternator defective, battery heavily discharged
|
- Check alternator and battery voltage, charge battery:
|
|
|
- Heavy battery load shortly after starting due to high charging current and current consumers
|
=> Increase revs slightly for a few minutes and switch off current consumers
|
|
|
- Transfer resistance in the current supply or the engine control unit earth connection
|
- Check engine control unit voltage supply => Page 24-121
|
|
|
- Current draw when ignition is off
|
- Eliminate current draw
|
|
More than 14.500 V
|
- Voltage regulator on alternator defective
|
- Check voltage regulator, replace if necessary:
|
|
|
- Excess voltage due to jump starting or quick charging unit
|
- Interrogate fault memory => Page 01-19
|
Evaluating display group 4, display zone 3 - Coolant temperature
|
Appears on display
|
Possible fault cause
|
Fault elimination
|
|
Less than 75 °C
|
- Engine too cold
|
- If necessary carry out test drive
|
|
|
- Coolant temperature sender or wiring to engine control unit
|
- Check coolant temperature sender
|
|
|
- Thermostat defective
|
- Check thermostat
|
|
Higher than 110 °C
|
- Dirt on radiator
|
- Clean radiator
|
|
|
- Radiator fan not working
|
- Check function
|
|
|
- Thermostat defective
|
- Check thermostat
|
|
|
- Coolant temperature sender or wiring to engine control unit
|
- Check coolant temperature sender
|
|
Constant -40.0 °C
|
- Wiring open circuit or short to positive
|
- Check coolant temperature sender
|
|
Constant 120.0 °C
|
- Short to earth
|
|
Evaluating display group 4, display zone 4 - Intake air temperature
|
Appears on display
|
Possible fault cause
|
Fault elimination
|
|
Constant -40.0 °C
|
- Wiring open circuit or short to positive
|
- Check intake air temperature sender
|
|
Constant 120.0 °C
|
- Short to earth
|
|
|
Display group 5 -Basic functions-
|
|
▪ Engine running at idling speed
|
|
Read measured value block 5
|
⇒
|
◂ Indicated on display
|
|
|
|
xxxx rpm
|
xxx.x %
|
xxx km/h
|
Text
|
|
|
|
|
1
|
2
|
3
|
4
|
◂ Display zones
|
Specification
|
Evaluation
|
|
|
|
|
|
Operating mode (idling, part throttle, enrichment, overrun)
|
Idling
|
---
|
|
|
|
|
Road speed
|
0 km/h
|
---
|
|
|
|
Engine load
|
12...18 %
|
=> Page 01-113
|
|
|
Engine speed (idling speed)
|
630...830 rpm1)
|
=> Page 01-100
|
1) Up-to-date specifications:
=> Exhaust emissions test binder
|
Display group 6 -Basic function-
|
|
▪ Engine running at idling speed
|
|
Read measured value block 6
|
⇒
|
◂ Indicated on display
|
|
|
|
xxxx rpm
|
xxx.x %
|
xxx.x °C
|
xx.x %
|
|
|
|
|
1
|
2
|
3
|
4
|
◂ Display zones
|
Specification
|
Evaluation
|
|
|
|
|
|
Elevation correction factor
|
-30.0...5.0 %
|
---
|
|
|
|
|
Intake air temperature
|
-40...120.0 °C
|
=> Page 01-109
|
|
|
|
Engine load
|
12...18 %
|
=> Page 01-113
|
|
|
Engine speed (idling speed)
|
630...830 rpm1)
|
=> Page 01-100
|
1) Up-to-date specifications:
=> Exhaust emissions test binder
Note on display zone 3:
The total temperature range is given as the specification. The displayed value must be above ambient temperature.
|