Test step
|
Testing of
|
▪ Test conditions - Additional work
|
Specification
|
Remedies if specification not attained
|
3
|
Power supply for power steering sensor
|
▪ Ignition off Unplug connector 3 from control unit -J500 ▪ Ignition on Check power supply at connector at control unit -J500 between contacts 1 and 2
|
10.0 -14.5 V
|
=> Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
4
|
Wiring
|
▪ Ignition off ▪ Select resistance measuring range ▪ (200 ω)
|
max.1.5 ω
|
- Unplug connector at control unit -J500 Check for open circuit or short to earth/positive in wiring => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
5
|
Function of Servotronic warning lamp -K92
|
▪ Fault memory interrogated and no fault stored in fault memory of power steering control unit -J500 ▪ Check fuse Si 38 ▪ Check fuse Si C
|
|
- Servotronic warning lamp lights => Current Flow Diagrams, Electrical Fault-finding and Fitting Locations binder
|
Test step
|
Testing of
|
▪ Test conditions - Additional work
|
Specification
|
Remedies if specification not attained
|
6
|
Data bus wires
|
▪ Ignition off ▪ Select 200 ω measuring range Unplug multi-pin connectors from control units linked to data bus (connection in dash panel wiring harness, contacts 19 and 20)
|
|
|
|
|
|
Test step 6: Continued on next page
|