audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

End of output > < Immobilizer fault table:
Electrical system, Self-diagnosis
Immobilizer self-diagnosis - immobilizer III
Erasing fault memory

Note:

If fault memory cannot be erased, interrogate fault memory again and eliminate fault.

Requirements:

  • ◆ Fault memory interrogated =>Page 01-156
  • ◆ All faults eliminated

After fault memory interrogation:

 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX
  • ‒ Press keys 0 and 5 to select "Erasing fault memory" function.
 
→ Indicated on display:
Rapid data transfer    Q
05 - Erasing fault memory
  • ‒ Confirm entry with Q key.
 
→ Indicated on display:
Rapid data transfer    ⇒
Fault memory erased

Fault memory has now been erased.

  • ‒ Press ⇒ key.
 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX

Notes:

 
→ Test sequence has not been correctly implemented if adjacent display appears.
Attention:
Fault memory not interrogated

 
→ Test sequence has not been correctly implemented if adjacent display appears.
Rapid data transfer    ⇒
Fault memory not interrogated

Keep exactly to test sequence: Interrogate fault memory first, eliminate any faults and then erase fault memory.

After erasing fault memory, faults are not updated until ignition has been switched off and on again.

End of output > < Immobilizer fault table: