audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Adaption > < Function status register
Description of operation
Description of operation
Production diagnosis (function status register) is a special mode for checking the wiring and correct functioning of the navigation system. It involves automatic checking of the individual fault locations, filing of the result in the so-called function status register (measured value block 007) and permanent storage.
Production diagnosis can be disabled/enabled by way of "Adaption" (channel number 03) → Chapter.
Production diagnosis is also disabled when a navigation CD is inserted.
The “Erasing fault memory” function also resets the function status register.
Test requirements:
t  No navigation CD inserted
t  Navigation system switched on
t  Tyre circumference adapted → Chapter
t  Adaption of number of pulses per wheel revolution performed → Chapter
t  Erase fault memory → Chapter
t  Drive vehicle at a speed of at least 10 km/h
t  With vehicle stationary, engage reverse gear for at least 2 seconds
Value 255 will be displayed in measured value block 007 (function status register) if production diagnosis has been implemented correctly (all test requirements met) and navigation system is OK.
   

Adaption > < Function status register