audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Disabling/enabling production diagnosis - Adaption channel 03 > < Change of tyre size - Adaption channel 01
Change to number of pulses per wheel revolution - Adaption channel 02
Change to number of pulses per wheel revolution - Adaption channel 02
   
Indicated on display:
–  Press keys 0 and 2 (“Channel 2”).
  Note
An incorrect entry can be corrected after pressing C key.
–  Confirm entry by pressing Q key.
 
Adaption
Enter channel number XX
Indicated on display:
Channel selected and number of pulses currently stored are displayed on top line.
–  Press key.
 
Channel 2     Adaption      4        ->
                            <-1 3->     
Indicated on display:
–  Enter new number of pulses (e.g.: 00008).
The number of pulses is always 8 for A2 with navigation system IV.
–  Confirm entry by pressing Q key.
 
Channel 2     Adaption      4        ->
Enter adaption value XXXXX
Indicated on display:
–  Press key.
 
Channel 2     Adaption      8        ->
                            <-1 3->     
Indicated on display:
–  Confirm entry by pressing Q key.
 
Channel 2     Adaption      8         Q
Store altered value?              
Indicated on display:
–  Press key.
 
Channel 2     Adaption      8        ->
Altered value stored
Indicated on display:
–  Press keys 0 and 6 (“End of output”).
–  Confirm entry by pressing Q key.
 
Rapid data transfer                HELP
Select function XX

Disabling/enabling production diagnosis - Adaption channel 03 > < Change of tyre size - Adaption channel 01